ASCA IgG semi quantitative kit WIESLAB® (ASCA151)
品牌:Svar Life Science
货号:
规格:
货期:

ASCA IgG semi quantitative kit WIESLAB® (ASCA151)

商品详情 参考文献 相关资料

ASCA IgG semi quantitative kit WIESLAB®

Add to my product list

Wieslab® ASCA test is an enzyme-linked immunosorbent assay (ELISA) for semi-quantitative/or qualitative detection of IgG autoantibodies against the mannan structure of Saccharomyces cerevisiae in human sera. The assay is used to detect antibodies in a single serum specimen. The results of the assay are useful as an aid in the diagnosis of Crohn's disease as well as in its differentiation from Ulcerative colitis.

40 patient samples can be tested in duplicate quantitatively alternatively 45 patient samples qualitatively. The test is completed within two hours.

Product code
ASCA151
Format
ELISA
Tests
Break apart microtitration strips (12x8) 96 wells
Calculation
Semi-quantitative and qualitative
Antigen
Mannan structure of Saccharomyces cerevisiae
Units
U/mL
Calibrators
5
Range
10-160 U/mL
Incubation time
30+30+60 min
Detection system
405 nm
Availability
CE marked. Not for sale in US
  • Intended use
  • Product Details
  • Kit Components

Intended use

The Wieslab® ASCA test kit is an enzyme-linked immunosorbent assay (ELISA) for detection and semi-quantitation of IgG antibodies to mannan of Saccharomyces cerevisiae in human sera. The assay is used to detect antibodies in a single serum specimen. The results of the assay are to be used as an aid to the diagnosis of Crohn’s disease.

FOR IN VITRO DIAGNOSTIC USE.

Background

Antibodies to the mannan structure of Saccharomyces cerevisiae has been known for several years and their association to Crohns disease discussed. Their diagnostic use have, however, not been appreciated until the ANCA test was established and it was shown that ANCA occurred in ulcerative colitis. Thus, it became possible to use these two tests in combination to differentiate Crohns disease from UC. The clinical presentation of these patients are often similar and then diagnosis depend on clinical, radiographic, endoscopic and laboratory data and especially in pediatric patients a serological test can be of use to avoid biopsy. The exact sensitivity and specificity is not yet settled. Studies indicate that 40-80% of UC patients have ANCA and 0-20% of Crohn´s patients have ANCA, while 0-10% of UC patients have ASCA and 50-70% of Crohn´s patients have ASCA. In one study the combination of positive ANCA with negative ASCA for diagnosis of UC had a sensitivity of 57% and specificity of 97%, while the combination of negative ANCA with positive ASCA for the diagnosis of Crohn´s had a sensitivity of 49% and a specificity of 97%.

Technical information

The wells of the microtitre strips are coated with mannan structure of Saccharomyces cerevisiae. During the first incubation, specific antibodies in diluted serum, will bind to the antigen coating.

The wells are then washed to remove unbound antibodies and other components.

A conjugate of alkaline phosphatase-labelled antibodies to human IgG binds to the antibodies in the wells in this second incubation.

After a further washing step, detection of specific antibodies is obtained by incubation with substrate solution. The amount of bound antibodies correlates to the colour intensity and is measured in terms of absorbance (optical density (OD)). The absorbance is then calculated against a calibrator curve and the results are given in arbitrary U/mL.

 

Kit components and storage of reagents

- One frame with grey coloured break apart wells (12x8) coated with mannan structure of Saccharomyces cerevisiae and one lid sealed in a foil pack with a dry pack.

- 1.5 mL negative control (NC) containing human serum in diluent.

- 1.5 mL positive control (PC) containing human serum in diluent.

- 13 mL conjugate containing alkaline phosphatase-labelled antibodies to human IgG (colour blue).

- 2 x 32 mL Diluent (Dil) containing PBS (red colour).

- 13 mL Substrate pNPP-solution.

- 30 mL wash solution 30x concentrated.

- Five calibrators containing human serum in diluent. 1.5 mL Cal 1 = 160 U/mL, 1.5 mL Cal 2 = 80 U/mL, 1.5 mL Cal 3 = 40 U/mL, 1.5 mL Cal 4 = 20 U/mL, 1.5 mL Cal 5 = 10 U/mL.

 

All reagents in the kit, except the wash solution, are ready for use and should be stored at 2-8° C.

Remove only the number of strips needed for testing, resealing the aluminium package carefully.

热销产品
热销产品排行榜
  • 关于我们
  • 购物流程
  • 支付方式
  • 配送方式

请打开QQ扫码联系
Copyright@ 2003-2024  进口试剂采购网版权所有     

BIOLEAF热搜   BIOLEAF试剂盒   BIOLEAF ELISA   BIOLEAF试剂   BIOLEAF品牌   BIOLEAF抗体   BIOLEAF耗材   BIOLEAF小仪器

sitemap   细胞库查询   危险品图标

本公司网站所展示销售的产品仅供科研!

         沪ICP备08023583号-6     
产品咨询
QQ扫码沟通
在线客服
服务电话
400-968-7988
扫码关注
微信公众号二维码

沪公网安备 31011202007338号