订购信息
上海拜力生物科技公司
Tel:400-968-7988    021-33779008
ViPrimePLUS Porcine Circovirus 1 qPCR Kit
品牌:Vivantis Technologies
货号:QV5002
规格:150 reactions
货期:

Home ViPrimePLUS Real-Time PCR Kits Veterinary Infection qPCR/RT-qPCR Kits Porcine ViPrimePLUS Porcine Circovirus 1 qPCR Kit ViPrimePLUS Porcine Circovirus 1 qPCR Kit Description The ViPrimePLUS Porcine Circovirus 1 qPCR Kit is a Taqman probe-based real-time PCR assay for the detection of Porcine Circovirus 1 genome in blood and tissues.

商品详情 参考文献 相关资料
Home  ViPrimePLUS Real-Time PCR Kits  Veterinary Infection qPCR/RT-qPCR Kits  Porcine  ViPrimePLUS Porcine Circovirus 1 qPCR Kit

ViPrimePLUS Porcine Circovirus 1 qPCR Kit

Description
The ViPrimePLUS Porcine Circovirus 1 qPCR Kit is a Taqman probe-based real-time PCR assay for the detection of Porcine Circovirus 1 genome in blood and tissues.
Porcine Circovirus (PCV) is a very small circular DNA virus that widely infects pigs. They are classified into PCV1 and PCV2, which differ in the ORF2 region that encodes for Cap. PCV1 was first discovered as a contaminant in a pig kidney cell line and it is a commonly present swine virus which has no known disease caused. Infection with PCV2 may cause typical PCVD lesions. Some PCV2 infected pigs may also develop the PCV-associated diseases (PCVAD) such as severe systemic PCV2 infection and Post-weaning Multisystemic Wasting Syndrome (PMWS), PCV2-associated pneumonia as part of the Porcine Respiratory Disease Complex (PRDC), PCV2-associated enteritis, PCV2-associated reproductive failure, and Porcine Dermatitis and Nephropathy Syndrome (PDNS). The symptoms of PCVAD develop slowly and progressively, and are often fatal, causing significant economic losses to pig producers worldwide. Vaccines are currently available to pig farms as a prevention measure. 
ViPrimePLUS Porcine Circovirus 1 qPCR Kit is intended for research use only.

Kit Component

  • PCV1 Primers and Probe Mix (PCV1 PPM)
  • Positive Control
  • Internal Extraction Control Primers and Probe Mix (IEC PPM)
  • Internal Extraction Control (IEC DNA)
  • Nuclease Free Water
  • Template Preparation Buffer

Product Specification

Technology Taqman probe-based real-time PCR assay
Type of Nucleic Acid Kit DNA
Kit Storage Shipped in room temperature, store at -20℃ on arrival
Sample Material Porcine samples (blood, tissues)
Gene Target PCV1
Detection Limit 10 to <100 copies per reaction
Sensitivity & Specificity Ct value 28±3 with probability of 95%
Controls Included • Internal Extraction Control (IEC) as inhibition control
• Positive control
Channels • FAM channels detect pathogen amplicons
• VIC/HEX channel detects IEC amplicons

Ordering Information

Catalog No Description Pack Size
QV5002 ViPrimePLUS Porcine Circovirus 1 qPCR Kit 150 reactions

Download
Manual

ViPrimePLUS Porcine Circovirus 1 qPCR Kit

热销产品
热销产品排行榜
  • 关于我们
  • 购物流程
  • 支付方式
  • 配送方式

请打开QQ扫码联系
Copyright@ 2003-2025  进口试剂采购网版权所有     

BIOLEAF热搜   BIOLEAF试剂盒   BIOLEAF ELISA   BIOLEAF试剂   BIOLEAF品牌   BIOLEAF抗体   BIOLEAF耗材   BIOLEAF小仪器

sitemap   细胞库查询   危险品图标

本公司网站所展示销售的产品仅供科研!

         沪ICP备08023583号-6     
产品咨询
QQ扫码沟通
在线客服
服务电话
400-968-7988
扫码关注
微信公众号二维码

沪公网安备 31011202007338号